Electrical Test Lab

The Electrical Test Laboratory is equipped with the advanced electrical parameter testing instruments, which provide not only precise electrical measurements for all kinds of inductor, common mode choke, transformer, bonded NdFeB, but also the blind electronic components analysis. In addition, signal analysis, power loss analysis, soft magnetic material B-H analysis, permanent magnetic material analysis, surface magnetic field distribution test, permeability and dielectric constant test are provided as well.


Order

Number

CategoryEquipmentKey Spec.Test Items
CNAS
1

AC

Signals

High Frequency 

Impedance Analyzer

Working frequency: 1M~1GHz

|Z|, |Y|, θ, R, X, G, B, L, C, D, Q, | Γ |, Γ x, Γ y, θ Γ, Vac, Iac, Vdc 1, Idc 1


Impedance testing scope: 120 mΩ ~ 52 kΩ
Accuracy: ±0.65%
2

Vector Network 

Analyzer

5 Hz to 3 GHz (pins 1 and 2), 5 Hz to 30 MHz 

(gain-phase test pin), 1 MHz resolution

1.S spec

2. Impedance Analyzer Function: ,IZI, θz , 

IYI, θy, Cp, Cs, Lp, Ls, Rp, Rs, D, Q, R, X, G, B,

3. Linear frequency scan, logarithmic 

frequency scan, segment sweep, power 

scan (in dBm), DC bias scan

3

Precision Magnetics

Analyzer

Testing frequency: 20Hz~3MHz1. L, |Z|, Rdc, C, Q, D, Rac, Ø, Turn-Ratio, LkAccredited
L: 0.1nH ~>1000H,R: 0.01mΩ~>2GΩ
Measurement accuracy: 0.1%

2. Magnetic core temperature 

characteristic test with thermostat

DC Bias Test SystemMaximum output current: 250A
Testing frequency: 20Hz~3MHz
1.LCR test or under DC bias conditions
Accuracy: ±(0.7%+25mA)

2.DC bias testing of devices at high and 

low temperatures used by thermostat

4

Multi-channel Data

Recorder

DC voltage range: 100mV~300V

Used in collecting infomation of voltage, 

resistance, temperature, and frequency


Resistance range: 100Ω~100MΩ

Temperature range: RTD: -200~600℃;

TC: -100℃~1200℃;thermistor: -80℃~150℃

Frequency range: 3Hz~300kHz
5

High Frequency LCR

Tester

Testing frequency: 20Hz~120MHz
L: 0.1nH to >2kH
R,Z,X: 0.01mΩ to >2GΩ
Q: 0.00001 to >1000
L, X, C, Y, Q, B, D, G, R, Z, θAccredited
Measurement accuracy: 0.05%
Analysis mode; Meter Mode
6

DC

Signals

Precision Micro

Resistance Meter

Resistance range: 0.001mΩ~3.5MΩDCR
Accredited
Accuracy: 0.02%;minimum resolution: 0.001mΩ
7
DC Power

Voltage range: 0~60V,Accuracy±0.5%Fs +3character

(10%~100%)

Irms current testing,operating life test
Accredited

Current: 0~100A,accuracy: ±0.5%Fs +3character

(10%~100%)

8

Pulse High Current

Inductance 

Measurement

Output current: 1A~1000A,output voltage: 10V~400V, 

inductance test accuracy: ±3%

Isat current


Testing Techniques

Impedance Analyzer

Microhmmeter

LCR Tester

B-H Analyzer

Permanent Magnetic Property Measuring Instrument

Withstand Voltage Tester

Surface Magnetic Field Distribution Measuring Instrument